Color | Temperature |
---|---|
Orange | 57*c |
Red | 68*c |
Yellow | 79*c |
Green | 93*c |
Blue | 141*c |
Black | 227*c |
Contact | Country |
---|---|
Flexible Hose | AISI 304 Stainless steel |
Nut | SWRM6K, Zinc plated |
Gasket Seal | NBR |
Isolation Ring | Nylon 6 |
Reducers | SPP (steel), Zinc plated |
Nipple | SPP (steel), Zinc plated |
Brackets | SPGC (steel), Zinc plated |
HD Standard and quick response Concealed Pendent Sprinkler is a thermo sensitive glass bulb spray sprinkler designed for installation on concealed pipe systems where appearance of smooth ceiling required
A tiny component on each head detaches at a specific temperature allowing water to flow. Similarly concealed cover plates break open during a fire at a lower temperature than the one that activates the sprinkler, allowing heat to rise to the sprinkler head
Bentech fire safety is proud to present the nation’s leading single and double head valve fire hydrants.
Valves are manufactured with best materials and high standards; these are the hydrants to turn to when you want safety delivered.
The items are Spindle, Bonnet, Gland bush, Check nut, Seat washer, Stop valve, Seat check nut, Hex nut, Hand wheel, Female outlet, Lower lug, Upper lug, Blank cap, Rubber ring, Chain.
Model MN009 Alarm Check Valve is a wet pipe sprinkler system water supply check valve that makes possible the installation of sprinkler system in buildings not subject to freezing temperatures
When a significant sustained flow of water occurs, such as from an open sprinkler, the alarm valve clapper lifts and allows water to enter the system. Simultaneously water enters an immediate chamber, which allows the water to activate the alarm.
Hose Reel Drum the model number is CSJR-08-A It has both the type Manual and Swinging Hose diameter and length is 19mm * 30m
Hose Nozzle model number is N-18-1 The nozzle diameter is 6mm Inlet size is 19mm
Fire hydrant box is installed on fire pipeline inside building
It consists of Two 15m RRL hose and one 63mm diameter hose nozzle
Most fire hydrants have two 2.5 inch hose connection outlets with 7.5 threads per inch and one 4.5 inch pumper connection outlet with 4 threads per inch
The RRL stands for Reinforced Rubber Lined hose is preferred by the fire fighters due to their excellent durability.
A jockey pump is a small pump connected to a fire fighting system and is intended to maintain pressure in a fire protection system
The jockey pump is essentially a portion of the fire pump system
A jockey pump is sized for a flow less than the flow to one sprinkler in order to ensure a system pressure drop
Jockey pumps should be sized for 3% of the flow of the main fire pump and to provide 10psi more than the main fire pump
The electrical motor driven main pump’s function is to start automatically when a hydrant valve or sprinkler is activated and to provide adequate quantity of water
Most of the main fire pumps are centrifugal pumps
Axial flow pump, Radial flow pump, Mixed flow pump
Diesel engine pump is heart of the pump room
In case of real fire there will be no electricity in that case diesel engine plays the important role in fire fighting system
It works on 12v 150ah battery, also it has 12v engine driven panel
Monsher Fire extinguishers are mainly of two types
Dry chemical powder ABC Model number MON/EX/ABC/01, MON/EX/ABC/02, MON/EX/ABC/04, MON/EX/ABC/06 and MON/EX/ABC/09
Carbon Dioxide type Model number Mon/CO2/2, MON/CO2/4.5, MON/CO2/9
ABC capacity 1kg, 2kg, 4kg, 6kg, 9kg
Co2 capacity 2kg, 4.5kg, 9kg
The GSM Auto Dialer that dials for emergency help when you are away used to monitor burglar alarm, fire alarm, motion detection, fuel levels, temperature changes, humidity levels, Co2, pressure switches, vibration, low or high village, glass breakage, control systems using any dry contact
Our leak detection systems can monitor up to 16 different leak zones and will give you audible and visual warning signs
The Rodent system installed by Bentech Fire Safety gives protection from harmful insects and prevents costly damage done by pests or rodents